Low Voltage Alert Alarm:
The Low Voltage Alert alarm will sound when the transmitter batteries reach the Alert Voltage
value programmed in the SYSTEM - ALARM menu. The alarm will sound each time the transmitter
battery voltage decreases by 0.1 volt. To clear this alarm, press the BACK/CANCEL key or the
Push-Button Rotary Dial. For more information, see the Voltage Alarm section on pages 61 and 62.
Temperature Alert Alarm:
The Temperature Alert alarm will sound when the TEMP1 and/or TEMP2 temperature reaches the
Alert Temperature value programmed in the SYSTEM - TELEMETRY menu. To clear this alarm,
press the BACK/CANCEL key or the Push-Button Rotary Dial. For more information, see the
Changing the Alert Temperature Value section on pages 64 and 65.
Voltage Alert Alarm:
The Voltage Alert alarm will sound when the receiver battery in your model reaches the Alert
Voltage value you've programmed in the SYSTEM - TELEMETRY menu. To clear this alarm, press
the BACK/CANCEL key or the Push-Button Rotary Dial. For more information, see the Changing
the Alert Voltage Value section on page 66.
Inactivity (Power ON) Alarm:
The Inactivity Alarm will sound if the transmitter is left on for a period of 10 minutes without any
control input from the user. This alarm alerts you to prevent unwanted draining of the transmitter
battery. To clear this alarm, either turn the transmitter OFF or press the BACK/CANCEL key or
the Push-Button Rotary Dial.
Low Voltage Limit Alarm:
The Low Voltage Limit alarm will sound when the transmitter batteries reach the Limit Voltage
value programmed in the SYSTEM - ALARM menu. This alarm can only be cleared by turning the
transmitter OFF and recharging or replacing the transmitter batteries. For more information, see
the Voltage Alarm section on pages 61 and 62.
LED 1 (Blue) and LED 2 (Red) can be used to determine various transmitter conditions at a glance. The LEDs will alert you to
various warnings and other transmitter conditions, as shown in the table below.
The MT-4S transmitter is equipped with several different safety alarms to warn you of an abnormal transmitter condition. In
addition, LED 1 and LED 2 can also be used to indicate various transmitter conditions.
Over Voltage Alarm:
The Over Voltage Alarm will sound if the transmitter battery voltage is greater than 9.6 volts. To clear
this alarm, turn the transmitter OFF and replace the transmitter battery with one that when fully
charged does not exceed 9.6 volts.


RF Output Signal OK
Throttle Offset Value ON with Positive or Negative Value
Telemetry Logger Function Operating
Anti-Lock Braking Function Operating
No Transmitter/Receiver Telemetry Connection
Telemetry Alarm Started
Low Voltage Alert Alarm Started
Bind Command Transmitted
Inactivity (Power ON) Alarm Started
Low Voltage Limit Alarm Started
Over Voltage Alarm Started
ON
Flash
Slow Flash
Fast Flash
ON
Flash
Flash
Flash Alternately
Flash
Fast Flash Alternately
Fast Flash Alternately
LED COLOR
LED CONDITION
Blue
Blue
Blue
Blue
Red
Red
Red
Blue and Red
Blue and Red
Blue and Red
Blue and Red
LED CONDITION DESCRIPTION


The audible alarms listed below may also be accompanied by an on-screen warning.